The Automatic Algorithm Generation (AAG) is the EICASLAB advanced feature,
specifically oriented to design the control according to the EICAS control design methodology.
The EICAS methodology gives a specific relevance to the plant state observer - the task of which
may be extended to estimate and to predict the disturbance acting on the plant - and to the reference
generator, used for computing the open-loop action.
| |
|
In synthesis, the control is performed by the resultant of three actions: |
|
the open loop action, which is given by the commands necessary to track the reference
signals computed on the basis of the plant simplified model;
the plant disturbance compensation, which is computed on the basis of the disturbance
predicted by the plant state observer;
the closed loop action, which is computed as the action necessary to correct the plant
state error with respect to the reference
|
|
The plant disturbance compensation is an original control feature, which allows to reduce significantly the control error. |
|
|
The designer can choose among three control basic schemes and for each one he has the option of selecting control algorithms at different levels of complexity. |
|
|
Starting from the control system requirements and from a simplified model of the plant to be controlled, AAG automatically generates the whole control algorithm. |
|
|
|